Strany 1 - User Manual for Sunways

MANUALUser Manual for Sunways Solar Inverters NT 2600, NT 4000 and NT 6000

Strany 2

Integration of the solar inverter into thePV systemDesign of the PV generatorThe technical data of the selected PVgenerator must be within the specifi

Strany 3

87ENStandard components of a PV systemDepending on the recommendations ofyour electrician, your PV system will con-sist of the following components:PC

Strany 4

Protection concept The following parameters are monitoredcontinuously and in parallel by the micro-controller and displayed on the screen:· AFI error

Strany 5

892.0 Information on installation

Strany 6 - 1.0 General information

Electrical safetyBefore opening the cabinet, the solarinverter must be disconnected from thegrid and from the PV generator. The solar inverter continu

Strany 7

91ENInformation on cleaningBefore cleaning, disconnect the systemfrom the power grid by opening the gridbreaker (main fuse) and open the DCswitch on t

Strany 8

2.2 InstallationThe solar inverter must be installed by a trained, qualified electrician. A special tool isnecessary for installation. Please read thi

Strany 9

93ENIf installing the solar inverter in a switchbox, ensure adequate heat dissipation.The ambient temperature must not fallbelow or exceed –25°C or +4

Strany 10

Electrical connection and cable entryFor installation, please observe theinstructions in the "Setup" leaflet!94!If the solar inverter is fi

Strany 11

95ENGrid connectionThe grid connection of the solar invertermust have 5 wires (L1, L2, L3, PE, N). Cablecross-sections of 5 x 4 mm2 are recommen-ded.T

Strany 12

300 mm510 mm180 mm

Strany 13

96You must use adequately dimensionedcable cross-sections in order to avoid aconsiderable increase in the grid impedan-ce between the domestic distrib

Strany 14

97ENPV generator connection· PreparationExecute the DC cabling according to yourelectrician's system dimensioning. Checkeach PV string for correc

Strany 15

98Important information· The direct PV generator voltage is availa-ble internally after connecting the PV generator to the solar inverter via the DC

Strany 16

99EN· The DC voltage can be up to 750 V. The unit may only be opened by a qualified electrician!· Always disconnect the PV generator side first by o

Strany 17

100Communication connectionsVia the communication connections (inter-faces), operating data can be retrievedfrom the data memory with an externalcompu

Strany 18

101EN· ConnectionRemove the cover of the solar inverterbefore connecting an interface cable. Payheed to all safety hints (Pages 90 and 91).You will fi

Strany 19

102Connecting the sensors· Optional irradiation sensorThe optional addition of an irradiationsensor (type Si-01TC-T from Ing.-BüroMencke & Tegtmey

Strany 20

ENConfiguration of the cable terminal block: Temperature sensor measuring signal: Temp Solar radiation measuring signal: SolarPositive supply, 5V:

Strany 21

1042.3 CommissioningConnect the solar inverter internally viathe ground cable (yellow-green) to thecabinet cover. (See also Setup, step 7)Put the cabi

Strany 22

EN105in cloudy weather. This is normal, and doesnot affect either the yield or the mode offunctioning of the solar inverter.· Switching offDisconnect

Strany 23

ENList of Contents1.0 General information1.1 Safety information1.2 Sunways Solar Inverters NT 2600, NT 4000 and NT 60002.0 Information on installation

Strany 24

However, language setting, LCD contrastand total energy offset (only to be usedin the event of replacement) must be configured directly on the unit. I

Strany 25

107ENThis is the only exception for which workmay be performed on the open unit undervoltage!Remove the cabinet cover to carry out theconfiguration.Th

Strany 26

108SOLAR INVERTERADDRESSPERFORMANCEANDOPERATING DATADATE TIMEHOURSESCCURUP/DWN+–MINUTES+–SECONDS+–SAVEESCCURESCCURESCCURUP/DWNADDRESS1 ... 99+–DAY+–MO

Strany 27

109LANGUAGESOFTWARE VERSIONENG./GER.+–UP/DWNUP/DWNLCD CONTRASTCONTRAST+–UP/DWNUP/DWNTOTAL POWEROFFSETkWh+–UP/DWNUP/DWNINCREMENT (100 OR 1)ESCCUR+/–+/–

Strany 28

1103.0 Information on operation

Strany 29

3.1 Monitoring and diagnosisDisplayThe dot matrix LCD display is integratedinto the cabinet of the solar inverter sothat it is easily visible. The dis

Strany 30

Data memoryYour solar inverter is equipped with aninternal data memory as standard. Thisdata memory provides you with a detailedview of the mode of fu

Strany 31

113EN3.2 Sunways NT Monitor softwareGeneral informationThe Sunways NT Monitor visualisation soft-ware was developed for PV system monito-ring and con

Strany 32

114from ICP-Deutschland, (available from yourspecialist dealer), which will guarantee reliable data transfer.The addresses of the solar inverter must

Strany 33 - (100 OR 1)

115Individual PV system with maximum distance of 50 m between solar inverter and PCRS 485+RS 485+RS 485–RS 485–GND_GTXRXGND_GTX2RX2 Yellow GreenBrownC

Strany 34 - 3.0 Information on operation

2.3 Commissioning3.0 Information on operation3.1 Monitoring and diagnosis3.2 Sunways NT Monitor software3.3 Fault indications3.4 Fault diagnosis 3.5

Strany 35

(2) Individual PV system with modem for remote inquiryRS 485+RS 485+RS 485–RS 485–GND_GTXRXGND_GTX2RX2 GreenYellowBrownConnection to modem via RS 232W

Strany 36

(3) PV system for 2 to 99 solar inverters with interface converter (IC)Connection to PC via RS 485/RS 232In order to connect several solar inverters t

Strany 37

118The signal is looped through all units. Two«RS 485+» terminals and two «RS 485-» terminals are located on each terminalblock. This means that the s

Strany 38

119RS 485+RS 485+RS 485–RS 485–GND_GTXRXGND_GTX2RX2 RS 485+RS 485+RS 485–RS 485–Connection to modem via RS 485/RS 232In order to connect several solar

Strany 39

120123456789Configuring the interface cablesCable type AFemale connector to PC,9-poleSignal cables to the solar inverter on X400TXRXGND123456789Cable

Strany 40

Locating jumper JP400 in the SunwaysSolar InverterPlease check the correct position of jum-per JP400, depending on your selectedcommunication circuit.

Strany 41

Sunways NT Monitor data acquisition· Online valuesDC voltage (U_DC), AC voltage (U_AC), AC current (I_AC), date, time, AC power,module temperature, mo

Strany 42

123ENOperation of Sunways NT MonitorAfter installing the Sunways NT Monitorsoftware on your PC, you can start the program. The word «Sunways» will now

Strany 43

124You can call up «Daily values» and«Monthly values» in the same way, byclicking on the respective keys.Exit the window with the «Close» key. You wil

Strany 44

3.3 Fault indicationsYour solar inverter operates fully automati-cally and maintenance-free. However, ifoperational faults occur due to external orint

Strany 45

EN4.0 Appendix 4.1 Subject and abbreviation index4.2 Function and information indexDesignation and descriptionFunctional principle and explanationsBlo

Strany 46

Display for AFI error protection:· Overheating faultYour solar inverter is designed for anambient temperature of up to +40°C.When the maximum upper te

Strany 47

1273.4 Fault diagnosis Fault displayOvertemperatureUDCOvervoltageCausesThe maximum permissibleambient temperature of40°C has been exceeded.The necessa

Strany 48

128Fault displayUAC_1UAC_3 AC under/over-voltageCausesThe grid voltage is too lowor too high.The cable cross-section inthe AC feed line to the solarin

Strany 49

129Fault displayAFI Residual currentIncorrect time,date are stored in Sunways NTMonitor withincorrect timedata.CausesThe AFI error is displayed

Strany 50

3.5 Warranty terms and conditions· Warranty periodThe warranty period is five years frompurchase of the solar inverter by the enduser. Please complet

Strany 51

131EN· Exclusion of liabilityWarranty claims and liability are excludedfor direct or indirect damages due to:· Interventions, modifications or attemp

Strany 52

4.0 Appendix132

Strany 53

4.1 Subject and abbreviation index133ENDesignationACAFI, RCDDCEMVEBINDCIPkWLCDMPPDescriptionAlternating Current: grid currentOperator protection in t

Strany 54

134DesignationGrid impedancePNDCPNACPTPVPV generator switchUNDCDescriptionAC resistance of grid, impedanceDC and AC rated power: Power which the inver

Strany 55

135EN4.2 Function and information indexFunctional principle and explanationsThe electrical energy of the PV generator is buffered by a capacitive sto

Strany 56 - 4.0 Appendix

821.0 General information

Strany 57

· Sensor interfaceAn irradiation sensor with integrated temperature sensor can be optionally con-nected to the relevant interface. Thisallows first ti

Strany 58

137ENcutoff threshold, which is dependent onthe performance class. The NT 2600 modelis switched off at an absolute residual cur-rent of 130 mA, the NT

Strany 59

DC-FILTERCAPACITIVE STORAGEBlock diagramHERIC®=≈DIFFERER. MEASUREMENTRTIRRADIATION SENSOR ANDTEMPERATURE SENSOR(OPT.)RS 232RS 485MICRO-CONTROLLERCONTR

Strany 60

CURRENT IMPRESSIONINDUCTORAC FILTER GRID PROTECTIONRESIDUAL CURRENTAFIDIFFERER. MEASUREMENTLCD-DISPLAY(2 LINES)KEYBOARDAND CESSINGAFIUACIACGRIDL1,L

Strany 61

140Technical dataSolar Inverter NT 2600Recommended PV generator powerRated input powerStand-by consumptionNight-time consumptionAC energy generated fr

Strany 62 - Block diagram

141Solar Inverter NT 4000 Solar Inverter NT 60002000 bis 4125 W3400 W9 W< 0.005 W15 W400 V350 ≤ UMPP≤ 650 V750 V410 V340 V10 A8.5 A2 (with adapter:

Strany 63

142Grid voltage monitoringEarth fault protectionOutput characteristicGrid connection fuse layoutRequired number of grid connection phasesNumber of fee

Strany 64

143threephaseRCD (universally sensitive) current source 25 A31RS 232, RS 485irradiation, temperatureLCD, 2 x 16 charactersIP 5495 per centfree convect

Strany 65

TYCO SOLARLOK connectorsThe TYCO SOLARLOK connectors are only approved for connection to permanently laid cables!They must not be disconnected under l

Strany 66

Any type of soiling (dust, humidity etc.)will negatively affect the operation of thesystem over the desired period of use. This applies particularly f

Strany 67

General safety informationAll safety hints contained in this sectionand throughout the User Manual must be complied with at all times to guaranteethe

Strany 68

Declaration of Conformity as per EG Low Voltage Guidelines 73/23/EWG, attachment III BWe herewith declare that the following product including the req

Strany 69

147ENDeclaration of Conformity as defined by the EMC guideline 89/336/EWG with revisions 91/263/EWG and 93/68/EWG.We herewith declare that the followi

Strany 70

148Declaration of Conformity of nominal power and maximum output power of solar inverters.ProductManufacturerType SunwaysNominal power SNMaximum outpu

Strany 71

149ENDeclaration of Conformity as defined by the guidelines for connection and grid feeding in parallel of in-plant generation on low-voltage-guidelin

Strany 72

150General exclusion of liabilityAlthough the accuracy and completenessof the information contained in theseinstructions have been checked with theutm

Strany 73

Concept and design: Denklabor Kommunikationsbüro GmbH, Lucerne/Switzerland

Strany 74

Sunways AG Photovoltaic TechnologyMacairestraße 3 - 5 D-78467 Konstanz Telefon +49 7531 996770Fax +49 7531 99677444E-Mail [email protected] www.sunwa

Strany 75

Opening the unit Before opening the cabinet, the unit mustalways be disconnected from the grid andfrom the PV generator. The unit continues to conduct

Strany 76 - 9-1-03-0-0 Version 03/05

85EN1.2 Sunways Solar Inverters NT 2600,NT 4000 and NT 6000Scope of supply· Sunways Solar Inverter in the NT series· Installation frame· Manual, set